-40%
N1201SA 137.5MHz - 2.7GHz UV RF Vector Impedance ANT SWR Antenna Analyzer Meter
$ 75.23
- Description
- Size Guide
Description
N1201SA UV RF Vector Impedance ANT SWR Antenna Analyzer Meter Tester137.5MHz - 2.7GHz
English verison with
Enlish instructions
Features:
working currency 137.5MHz~2700MHz
stepped frequency 1kHz
Display 2.4cun TFT trdp
resolution ratio 320*240(QVGA)
2000mAH(7.4Wh)
power consumption <1.5W
charge current 400mA
charge port USB
Auto power off can be set 5-60minutes
measured parameters resistence reactance standing wave s11
resolution ratio 4 number
frequency accuracy about 5ppm
Connector SMA-K
measurement range:
impedance:0.1~1000
standing wave:1.000~65
s11(dB):0dB~-60dB
Working temperature:0~40 degree
atmospheric pressure:860hPa~1060hPa
Description:
This instrument has four interfaces: single point measurement, scanning, system information, correction and calibration
The default boot into single-point measurement interface.
Note: For the convenience of the user, each time calibration correction options will automatically change to the user calibration. Meanwhile, in order to ensure the integrity of the calibration, the calibration process, the automatic shutdown function fails, the consistent boot.
Startup and shutdown
Hold down the CTRL key off press the power switch button.
The boot state, long press (2S above) the switch button, after the release, the instrument will shut down
The boot state, long press (2S above) the switch button, after the release, the instrument will shut down
Recommend the use
1, in order to ensure the accuracy of measurement and calibration, preheat the instrument at least 15 minutes.
2, try to use good quality RF cable and connectors.
3, calibrated cable marked to the next may not need to calibrate and direct use.
4, test cable process affect the measurement accuracy, it is recommended that, where possible, do not choose too long test cable.
5, measurement and calibration before, make sure you are not in a strong wireless signal, so as to avoid interference caused by inaccurate measurements.
6, if the impedance measurements themselves do not understand, you can refer to a vector network analyzer instructions and tutorials. This instrument is equivalent to a single-port vector network analysis.
Payment
We accept PayPal only.
We only ship item to your PayPal verified address.
Payment must be received within 3 days from the date of purchase.
Orders will be processed and dispatched within 3 days normally
Terms Of Sales
1. Our listing price includes the value of goods,packaging cost,and export
taxes,not including international import duties.
2. Import duties,taxes,and charges are not included in the item price or shipping fee.
3. The import duties are buyers' responsibility.Please check with your country's
customs office determine what these additional costs will be prior to your
purchase.
4. All disputes arising from the import duties will be submitted to eBay for solution.
Feedback
Any questions, pls. contact us via ebay message or email us.We will reply your message within 48 hours. If you do not receive our reply within 48 hours, pls. post a message again because sometimes our message system may block some emails.
Our aim is to provide Top Level Customer Service, your recognition will encourage us greatly and serve you better. We strive to keep all our customers satisfy.
We greatly appreciate your POSITIVE feedback. Please do NOT leave negative feedback without asking for help.Thanks!
Contact Us
We will always do our up most to exceed your expectations in customer service, communication and dispatching of your orders.